![]() Cast Circulation Heater For Chemical ApplicationAn engineer with a unique chemical heating application found Durex's website on the internet and contacted us regarding heating a mixture of chemicals used in a Thermal Fogging Machine. John Sidbeck, a Durex application engineer, called the potential customer to discuss the electric heating application in detail.The application was to pump a premixed blend of 80% dipropylene glycol solvent and 20% Fungicide with the following specifications:
After detailed discussion, it was determined that the maximum power requirement would be 940 watts. John recommended Durex' DFX250 Cast Circulation heater as a solution. The DFX250 is a robust low mass circulation heater that provides a quick thermal response. The cast circulation heater assembly is a designed integral 316 stainless steel tube and tubular heater that are in a helix layout. This design maximizes heat transfer in variable flow rate gas and fluid applications. Learn more about all our electric heating solutions. Give us the opportunity to help you with all your heating and sensing requirements, contact us or request quote today! Durex Industries designs, engineers & manufactures electric heaters, process heating systems, temperature sensors and temperature controls. |