Click image to enlarge

Sanitary RTD

0.00
Contact Us Request a Quote

RS style sanitary resistance temperature detectors are commonly used in the food and dairy industries. The sanitary fittings are welded to the stainless steel sheath and polished to meet 3-A Sanitary Council Standards. The highly polished finish prevents the growth of bacteria or other corrosive accumulation that might otherwise develop on standard RTD assembly connections.

There are various fitting sizes and styles available. Care must be taken to ensure that the correct fitting is specified. In addition to the sanitary fittings, typical RTD sanitary temperature sensor probes are equipped with an FDA compliant thermoplastic head, which has a gasket and is suitable for wash down applications. Various element types and wiring configurations are available.

RTD With Sanitary Fitting

The RSF style sanitary resistance temperature detector has a stainless steel cap, 316 stainless steel nipple, and a reduced tip.

Sanitary-RTD-RSF
 
Part Number Configuration - Example:  RSF-HB-6D12D-T1W

RSW - Element TypeWiring ConfigurationSheath MaterialSheath DiameterImmersion Length "L"Cap TypeCap SizeTerminal Head

 

RTD With Sanitary Wells

The RSW style sanitary resistance temperature detector has a stainless steel cap and well.

Sanitary-RTD-RSW
 
Part Number Configuration - Example:  RSW-ED-6H06H-T1W

RSW - Element TypeWiring ConfigurationSheath MaterialSheath DiameterImmersion Length "L"Cap TypeCap SizeTerminal Head

Sanitary RTD Specs & Options

Back to Top

Element Types

Element Type Code Element Type Description
A 100 ohm Platinum, Class B .00385 Coefficient
B 100 ohm Platinum, Class A .00385 Coefficient
E 1000 ohm Platinum, Class B .00385 Coefficient
G 100 ohm Platinum, Class B .00392 Coefficient
 

Wiring Configurations

Wiring Configuration Code Wiring Configuration Description
A Single, 2 Wire
B Single, 3 Wire (Minimum sheath diameter .156”)
C Single, 4 Wire (Minimum sheath diameter .188”)
D Dual, 4 Wire (Minimum sheath diameter .188”)
E Dual, 6 Wire (Minimum sheath diameter .250”)
 

Sheath Material

Sheath Material Code Sheath Material Description
6 316 Stainless Steel
 

Sheath Diameter

Sheath Diameter Code Sheath Diameter Description RTD Style
C .188” or 3/16” O.D. RSF
D .250” or 1/4” O.D. RSF
H .500 or 1/2” Outer Diameter RSW
 

Dimensional Chart

"L" Dimensions "B" Dimensions "A" Dimensions Fractional Dimension
Letter Code
“L” dimensions are specified in whole inches and a single alpha character which represents a fraction. Enter the three digit code as follows: “B” dimensions are specified in fractions from ⅛” to 1”. Use the single alpha character to indicate the tip length. Enter the code as follows: “A” dimensions are
specified in whole inches only. Enter the three digit code as follows:
1/16" A 11/16" L
1/8" B 3/4" M
3/16" C 13/16" N
1/4" D 7/8" P
5/16" E 15/16" R
3" 030 10 5/8" 10K 3/8" F 1" S
4 1/2" 04H 12" 120 1/8" B 5/8" K 9" 009 7/16" G 0 No
6 1/4" 06D 15 3/8" 15F 1/4" D 3/4" M 12" 012 1/2" H  
7 7/8" 07P 17 3/4" 17M 3/8" F 7/8" P 36" 036 9/16" J
9 5/8" 09K 22 1/8" 22B 1/2" H 1" S 144" 144 5/8" K
 

Cap Type

Sanitary Cap Type Code Sanitary Cap Type Description
T 16A Plain Cap, Tri Clover
U 16A Plain Cap & 13H Hex Union Nut, Tri Clover
 

Cap Size

Sanitary Cap Size Code Sanitary Cap Size Description
1 1 1/2” (Tube Outer Diameter)
2 2” (Tube Outer Diameter)
3 2 1/2” (Tube Outer Diameter)
4 3” (Tube Outer Diameter)
 

Terminal Head Options

Terminal Head Code Terminal Head Description
A Aluminum Screw Cover Head; 1/2” NPT Conduit Connection
W White Polypropylene FDA Compliant Screw CoverHead; 1/2” NPT Conduit Connection


Custom Options Available - Contact us for Engineering Assistance.